5 10 20 50
R [%]
500
200
100
50
20
10
5
2
1
6
5
3
2
4
1
64 D [m]
Figure 92: Scanning range and required remission for warning fields (devices with a max.
pr
otective field range of 9.0m)
R Required minimum remission in %
D Scanning range in m
1
Black shoe leather
2
Matt black paint
3
Gray cardboard
4
Writing paper
5
White plaster
6
Reflectors>2,000%, reflective tapes>300%
23)
13.6 Scan plane
Overview
In pr
actice, the scan plane is slightly conical and tilted.
For the devices with the name suffix “PS”, the tolerances are smaller than for devices
without the name suffix.
23)
T
he measured values are less accurate for reflectors or reflective surfaces because the distance measurement is designed for lower
remission values.
TECHNICAL DATA 13
8020200/1NTM/2024-06-03 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherNet/IP™
181
Subject to change without notice