4.5 Integration into the network
4.5.1 Network topology
The device is suitable for the following network topologies:
St
ar
Line
Ring (Device Level Ring, DLR)
4.5.2 Network services and ports
Table 5: Network services and ports
Use Protocol Source Source port Target Destination port
SNMP UDP SNMP client Selected by the cli‐
ent
microScan3 161
microScan3 161 SNMP client Selected by the cli‐
ent
DHCP UDP microScan3 68 DHCP server 67
DHCP server 67 microScan3 68
SNTP UDP microScan3 123 NTP server 123
NTP server 123 microScan3 123
EtherNet/IP
(Explicit Me
ssaging)
TCP EtherNet/IP client Selected by the cli‐
ent
microScan3 44818
microScan3 44818 EtherNet/IP client Selected by the cli‐
ent
EtherNet/IP (ListI‐
dent
ity via UDP)
UDP EtherNet/IP client Selected by the cli‐
ent
microScan3 or Lim‐
ited Broadcast or
Directed Broadcast
44818
microScan3 44818 EtherNet/IP client Selected by the cli‐
ent
EtherNet/IP (cyclic
d
ata transmission,
implicit messaging,
unicast)
UDP Originator (e.g. con‐
troller)
2222 Target (micro‐
Scan3)
2222
Target (micro‐
Scan3)
2222 Originator (e.g. con‐
troller)
2222
CoLa2 (protocol
from SICK, configu‐
ration and diagnos‐
tics)
TCP CoLa2 client, e.g.
computer with
Safety Designer
Selected by the cli‐
ent
microScan3 2122
microScan3 2122 CoLa2 client, e.g.
com
puter with
Safety Designer
Selected by the cli‐
ent
CoLa2 (protocol
from SICK, device
search)
UDP Computer with
Safety Designer
30718 … 30738 microScan3 or Lim‐
ited Broadcast or
Directed Broadcast
30718
microScan3 30718 Computer with
Safety Designer (if
in the same subnet)
or Broadcast (if in a
different subnet)
30718 … 30738
Data output in
transmit mode con‐
tinuous
UDP microScan3 Randomly selected Target computer Configurable
PROJECT PLANNING 4
8020200/1NTM/2024-06-03 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherNet/IP™