Error type Brief description Cause Troubleshooting
T1 Temperature error The operating temperature of the
s
afety laser scanner has exceeded
or fallen below the permitted range.
Chec
k whether the safety laser
scanner is being operated in
accordance with the permissible
ambient conditions.
W1 Warnings exceed toler‐
ance t
ime
The combination of multiple warn‐
ings has resulted in an error. The
tolerance time of 1s has been
exceeded as there are multiple
warnings.
Use S
afety Designer to check
what warnings exist.
11.4 Diagnostics using Safety Designer
The following diagnostics tools are available in the device window:
D
ata recorder
Event history
Message history
Status inputs and outputs
The following interfaces are suitable for diagnostics:
U
SB 2.0 mini-B (female connector)
21)
Ethernet
21)
T
he USB connection may only be used temporarily and only for configuration and diagnostics.
TROUBLESHOOTING 11
8020200/1NTM/2024-06-03 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherNet/IP™
159
Subject to change without notice

Table of Contents