Name Use Data type Definition Values Safety implica‐
t
ion
TriggerRunMode Safety function BOOL Start safety function
Restarts the safety
function, e.g. if it
was stopped or after
an application error.
(The device must be
restarted after a device
error.)
0 = no start com‐
mand
Safety-relevant
parameter
0-1-0 = start
s
afety function
(duration of sta‐
tus 1 ≥ 120ms)
1 = ignored
1)
Control inputs 9 (E1) … 16 (H2) are only available for the Pro performance package.
2)
Cut-off paths 5 to 8 are only available for the Pro performance package.
13.9.3.1.2 Output of the device (input of the control)
Table 56: Output of the device (input of the control)
Name Use Data type Definition Values Safety implica‐
t
ion
ApplicationError Diagnostics BOOL Application error
Signals whether an
application error is
present, causing the
safety function to be
paused. To resolve this,
rectify the cause of the
error and then restart
the safety function.
0 = no applica‐
tion error
Parameter with‐
out safety impli‐
cation
1 = application
error
ContaminationError Diagnostics BOOL Contamination error
Opt
ics cover is dirty. All
safety outputs in the
OFF state. Clean the
optics cover.
0 = no contami‐
nation error
Parameter with
implication for
the safety func‐
tion
1 = contamina‐
t
ion error
ContaminationWarning Diagnostics BOOL Contamination warning
Opt
ics cover is dirty.
Clean the optics cover.
0 = no contami‐
nation warning
Parameter with‐
out safety impli‐
cation
1 = contamina‐
tion warning
control input 1 (A1) Safety function BOOL Control input 1 (A1)
St
ate of the static con‐
trol input for monitoring
case switching.
0 = logic status
of the control
input is 0
Safety-relevant
parameter
1 = logic state of
the control input
is 1
control input 2 (A2)
…
cont
rol input 16 (H2)
Safety function BOOL Control input 2 (A2) …
16 (H2)
State of the static con‐
trol input for monitoring
case switching.
0 = logic status
of the control
input is 0
Safety-relevant
parameter
1 = logic state of
the control input
is 1
ControlInputsValid Safety function BOOL State of the valid static
c
ontrol inputs
0 = inputs invalid Safety-relevant
parameter
1 = inputs valid
13 TECHNICAL DATA
196
O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherNet/IP™ 8020200/1NTM/2024-06-03 | SICK
Subject to change without notice