Name Use Data type Definition Values Safety implica‐
t
ion
CurrentMonitoringCaseNoTa‐
ble1
Diagnostics USINT Current monitoring
case (Monitoring case
table 1)
Signals the current
(active) monitoring case
of monitoring case
table 1.
0 = no monitor‐
ing case is active
Parameter with‐
out safety impli‐
cation
1 … 254 = num‐
ber of t
he current
(active) monitor‐
ing case
CurrentMonitoringCaseNoTa‐
ble2
Diagnostics USINT Current monitoring
c
ase (Monitoring case
table 2)
Signals the current
(active) monitoring case
of monitoring case
table 2.
0 = no monitor‐
ing case is active
Parameter with‐
out safety impli‐
cation
1 … 254 = num‐
ber of the current
(active) monitor‐
ing case
CurrentMonitoringCaseNoTa‐
ble3
Diagnostics USINT Current monitoring
c
ase (Monitoring case
table 3)
Signals the current
(active) monitoring case
of monitoring case
table 3.
0 = no monitor‐
ing case is active
Parameter with‐
out safety impli‐
cation
1 … 254 = num‐
ber of the current
(active) monitor‐
ing case
CurrentMonitoringCaseNoTa‐
ble4
Diagnostics USINT Current monitoring
c
ase (Monitoring case
table 4)
Signals the current
(active) monitoring case
of monitoring case
table 4.
0 = no monitor‐
ing case is active
Parameter with‐
out safety impli‐
cation
1 … 254 = num‐
ber of t
he current
(active) monitor‐
ing case
DeviceError Diagnostics BOOL Device error
S
ignals whether a
device error (serious
error) is present, caus‐
ing the safety func‐
tion to be paused. To
resolve this, rectify the
cause of the error and
then restart the device.
0 = no device
error
Parameter with‐
out safety impli‐
cation
1 = device error
ManipulationStatus Diagnostics BOOL Manipulation
S
ignals if manipulation
has been detected
and the safety outputs
are therefore in the
OFF state, for example
because the device has
not detected an object
over a long period of
time.
0 = no manipula‐
tion detected
Parameter with
implication for
the safety func‐
tion
1 = manipulation
detected
NonsafeCutOffPath01 Additional func‐
t
ion
BOOL Cut-off path 01 (Not
safety-related)
The signal is ON if
the currently monitored
field in the cut-off path
is free.
0 = OFF state,
detection in field
Parameter with‐
out safety impli‐
cation
1 = ON state,
field free