Attribute ID Access rule Name Data type Description
Dec Hex
11 0x0B Get Device Status USINT Device status
•
0: unc
lear device status
•
1: device start
•
2: service mode (e.g. firmware update,
optics cover calibration)
•
3: normal operation
•
4: device is waiting (e.g. for communica‐
tion partner or input signal)
•
5: waiting recommended (e.g. contami‐
nation warning)
•
6: waiting required (e.g. configuration
incompatible)
•
7: correctable error (e.g. configuration
error, network error)
•
8: serious error (e.g. contamination
error, configuration error, network error)
12 0x0C Get RequiredUserAc‐
t
ion
UINT Note on troubleshooting
•
Bit 0.0: configure device, verify configu‐
ration
•
Bit 0.1: Test configuration, test device
variant
•
Bit 0.2: check communication partner,
check manipulation
•
Bit 0.3: check input signals, check net‐
work and other connections
•
Bit 0.4: check error messages
•
Bit 0.5: configure device (including net‐
work settings)
•
Bit 0.6: check firmware
•
Bit 0.7: wait a few seconds
Services
•
G
et_Attribute_List
•
Get_Attributes_All
•
Get_Attribute_Single
13.9.3 Assemblies
13.9.3.1 Available data
13.9.3.1.1 Input of the device (output of the control)
Table 55: Input of the device (output of the control)
Name Use Data type Definition Values Safety implica‐
t
ion
ActivateCaseSwitching Safety function BOOL Monitoring case switch‐
in
g
Activates switching
between monitoring
cases. Only valid sig‐
nals are then permitted
for switching between
monitoring cases.
0 = switching
between monitor‐
ing cases not
activated
Safety-relevant
parameter
1 = switching
between monitor‐
ing cases acti‐
vated
ActivateStandbyMode Additional func‐
tion
BOOL Activate sleep mode
Activates sleep mode.
0 = no sleep
mode
Parameter with‐
out safety impli‐
cation
1 = sleep mode
TECHNICAL DATA 13