13.3 Data sheet
13.3.1 microScan3 – EtherNet/IP™
Features
T
able 41: Features
microScan3 Core – Ether‐
Ne
t/IP™
microScan3 Pro – Ether‐
Net/IP™
Protective field range
Devices with a max. protec‐
t
ive field range of 4.0m
≤ 4.0m, details: see "Sensing range", page 177
Devices with a max. protec‐
tive field range of 5.5m
≤ 5.5m, details: see "Sensing range", page 177
Devices with a max. protec‐
tive field range of 9.0m
≤9.0m, details: see "Sensing range", page 177
Scanning range of the refer‐
enc
e contour field
Same as protective field range, see "Sensing range", page 177
Scanning range of the con‐
tour detection field
Same as protective field range, see "Sensing range", page 177
Warning field range
Devices with a max. protec‐
t
ive field range of 4.0m
≤ 40m
Devices with a max. protec‐
tive field range of 5.5m
≤ 40m
Devices with a max. protec‐
t
ive field range of 9.0m
≤ 64m
Fields ≤8 ≤128
Simultaneously monitored fields
Devices with a max. protec‐
t
ive field range of 4.0m
≤4 ≤8
Devices with a max. protec‐
tive field range of 5.5m
≤4 ≤8
Devices with a max. protec‐
tive field range of 9.0m
≤4
Simultaneous cut-off paths
Devices with a max. protec‐
t
ive field range of 4.0m
≤4 ≤8
Devices with a max. protec‐
t
ive field range of 5.5m
≤4 ≤8
Devices with a max. protec‐
tive field range of 9.0m
≤4
Field sets ≤8 ≤128
Monitoring cases ≤8 ≤128
Scanning angle 275° (–47.5° … 227.5°) 275° (–47.5° to 227.5°)
Protective field resolution 30mm, 40mm, 50mm, 60mm, 70mm, 150mm, 200mm
1)
Response time
Devices with a max. protec‐
t
ive field range of 4.0m
≥ 95ms, details: see "Response times", page 176
Devices with a max. protec‐
t
ive field range of 5.5m
≥ 95ms, details: see "Response times", page 176
TECHNICAL DATA 13
8020200/1NTM/2024-06-03 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherNet/IP™
171
Subject to change without notice