Version number Amendments and new functions EtherNet/IP: Minor Revi‐
sion
V 1.2.0
D
eviating multiple sampling after
object detection can be config‐
ured
Collision protection field
Speed-dependent monitoring
case switching
Assembly 105
Interfaces and selected functions
can be activated or deactivated
According to the current specifi‐
cations for CIP Safety, only the
extended format is supported, but
no longer the base format
Up to 4 simultaneous monitoring
case tables
New Always ON (NON-safe) function
in monitoring case tables
4
Revision
T
he different revision statuses of the devices are identified by “Rev” followed by a three-
digit version number. New devices have a label which indicates the revision status.
Table 39: Revision
Version number Amendments and new functions
Rev 1.0.0
F
irst released version
Rev 1.1.0
Int
ernal change to components, no change in function
Rev 1.2.0
Internal change to components, no change in function
Rev 1.3.0
Data output: Accuracy of angle specification improved
Adaptation of detection behavior for optimized safety and avail‐
ability
Rev 1.4.0
Int
ernal change to components, no change in function
Rev 1.5.0
Internal change to components, no change in function
Rev 1.6.0
Internal change to components, no change in function
In some cases, new system plugs are not suitable for older devices.
N
ew system plugs have a label which indicates the devices for which they are suitable.
Table 40: Compatibility
Label on the device Label on the system plug Compatible
Yes
Only compatible with Rev ≥1.1.0 Information is available
from your SICK subsidiary.
Rev 1.1.0 (or higher) Yes
Rev 1.1.0 (or higher) Only compatible with Rev ≥1.1.0 Yes
13 TECHNICAL DATA