microScan3 Core – Ether‐
Ne
t/IP™
microScan3 Pro – Ether‐
Net/IP™
Devices with a max. protec‐
tive field range of 9.0m
≥115ms, details: see "Response times", page 176
Scan cycle time
Devices with a max. protec‐
t
ive field range of 4.0m
30ms or 40ms (adjustable)
Devices with a max. protec‐
tive field range of 5.5m
30ms or 40ms (adjustable)
Devices with a max. protec‐
t
ive field range of 9.0m
40ms or 50ms (adjustable)
Generally necessary protective field supplement (TZ = tolerance zone of the safety laser
scanner)
Devices with a max. protec‐
t
ive field range of 4.0m
65mm
Devices with a max. protec‐
tive field range of 5.5m
65mm
Devices with a max. protec‐
tive field range of 9.0m
100mm
Additional supplement
Z
R
f
or reflection-based meas‐
urement errors
350 mm
Distance of mirror rotational
a
xis (zero point of x and y
axis) to mounting surface on
rear side of device
56 mm
Distance between center
point of scan plane and top
edge of the housing
40,1 mm
Multiple sampling 2 … 16
2)
2 to 16
2)
1)
Protective field resolution 60mm only available for devices with max. protective field range of 9.0m.
2)
Can be adjusted collectively for all fields or individually for each field.
Safety-related parameters
T
able 42: Safety-related parameters
microScan3 Core – Ether‐
Ne
t/IP™
microScan3 Pro – Ether‐
Net/IP™
Type Type 3 (IEC61496)
Safety integrity level SIL 2 (IEC 61508) SIL 2 (IEC61508)
SIL claim limit SILCL 2 (IEC 62061) SILCL 2 (IEC62061)
Category Category 3 (ISO 13849-1)
Performance level PL d (ISO 13849-1) PL d (ISO13849-1)
PFH
D
(me
an probability of a
dangerous failure per hour)
8 × 10
–8
T
M
(mis
sion time) 20 years (ISO 13849-1) 20years (ISO 13849-1)
Safe status when an error
oc
curs
The safety outputs via the network are logic 0.
13 TECHNICAL DATA
172
O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherNet/IP™ 8020200/1NTM/2024-06-03 | SICK
Subject to change without notice