EasyManua.ls Logo

SICK EtherNet/IP microScan3 - Page 173

SICK EtherNet/IP microScan3
224 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Interfaces
T
able 43: Interfaces
microScan3 Core – Ether‐
Ne
t/IP™
microScan3 Pro – Ether‐
Net/IP™
Safety outputs via network
Quantity
Devices with a max. protec‐
t
ive field range of 4.0m
4 8
Devices with a max. protec‐
tive field range of 5.5m
4 8
Devices with a max. protec‐
tive field range of 9.0m
4
Duration of OFF state ≥ 80ms ≥80ms
Automated restart after 2s … 60s (can be configured) 2s to 60s (can be configured)
Voltage supply
Connection type Male connector, M12, 4-pin, A-coding
Length of cable (power supply unit tolerance ±5%)
Length of cable with
0.25mm² c
onductor cross
section
≤ 100m ≤100m
USB
Connection type USB 2.0 mini-B (female connector)
Transmission rate ≤ 12Mbit/s ≤12Mbit/s
Length of cable ≤ 5m ≤5m
EtherNet/IP
Connection type M12 female connector, 4-pin, D-coded
Transmission rate ≤100Mbit/s
Length of cable ≤100m
Services
1)
E
therNet/IP™ CIP Safety™
CoLa2 (configuration and diagnostics with the Safety
Designer)
Data output
DHCP
SNMP
SNTP (client and server)
Supported protocol versions
Common Industrial Protocol: The CIP Networks Library Vol‐
ume 1
EtherNet/IP™: The CIP Networks Library Volume 2
CIP Safety™: The CIP Networks Library Volume 5
1)
The SNTP server provides the time since the device was switched on.
Electrical data
T
able 44: Electrical data
microScan3 Core – Ether‐
Ne
t/IP™
microScan3 Pro – Ether‐
Net/IP™
Operating data
Protection class III (IEC 61140) III (IEC61140)
Supply voltage V
S
24VDC (16.8V … 30VDC)
(SEL
V/PELV)
1)
24VDC (16.8V to 30VDC)
(SELV/PELV)
1)
TECHNICAL DATA 13
8020200/1NTM/2024-06-03 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherNet/IP™
173
Subject to change without notice