Display Device or configura‐
t
ion
Meaning
Devices and configu‐
r
ations with more than
4 configured safety
outputs
For one or more cut-off paths, the following
applies: Detection in the protective field or
there is a warning field in the active monitoring
case. The associated safety outputs are in the
OFF state.
•
Left digit: the number of safety outputs in
the OFF state
•
Right digit: the number of configured safety
outputs
Configuration with
r
estart interlock
Protective field is clear, reset can take place.
Configuration with
r
estart interlock
Reset button pressed Safety output in the OFF
state.
Configuration with
r
estart interlock
Reset button pressed Safety output in the ON
state.
Configuration with
aut
omated restart
after a time
Protective field is clear, configured time to
restart expires.
Configuration with at
le
ast one warning field
Detection in the warning field (left col‐
umn:number of warning fields with detection,
right column:number of warning fields in the
current monitoring case).
Display flashes
All devices and config‐
ur
ations
Error. All safety outputs in the OFF state. Addi‐
tional information: see "Error indication on the
display", page 157.
Display flashes
All devices and config‐
ur
ations
Contamination warning. Check the optics cover
for damage. Clean the optics cover.
Display flashes
All devices and config‐
ur
ations
Contamination error. All safety outputs in the
OFF state. Check the optics cover for damage.
Clean the optics cover.