M5 fixing screw
Approach
1.
First mount the two O-Fix brackets at the correct positions, but do not yet tighten
the fixing screws.
2. Insert the twin stick between the two O-Fix brackets. For applications in which
strong vibrations could occur, from a device length of 600 mm, stick the twin stick
to the mounting surface with two-sided tape (see !in figure 40).
3. Then fasten the screws of the O-Fix bracket with a torque of 5 Nm. Higher torques
can damage the brackets; lower torques provide inadequate protection against
displacement.
Figure 40: Mounting the miniTwin4with O-Fix bracket
T
able 6: Drilling distance for mounting with O-Fix bracket
Protective field height of the twin stick in mm Drilling distance L in mm
120 132.6
180 192.6
240 252.6
300 312.6
360 372.6
420 432.6
480 492.6
540 552.6
600 612.6
660 672.6
720 732.6
780 792.6
840 852.6
900 912.6
960 972.6
1020 1,032.6
MOUNTING 5
8012624/10OM/2018-08-09 | SICK O P E R A T I N G I N S T R U C T I O N S | miniTwin4
51