MLG Parametrier Software Version 2.15
MLG System information
Configuration
Outputs
Output Q1
Output Q2
Output Q3
Contamination output (Alarm)
Off delay
Hysteresis
Contamination output
(Alarm)
/ LBB >= 1
LBB >= 1 AND LBB <=30
0 ms
0 Beams
3 Beams (Q3)
1
9
2
3
Output QA1
Output QA2
Output Q4 Inactive
4
5
FBB = 4-20 mA
LBB = 4-20 mA
6
7
8
Figure 18: MLG-1 – “MLG System Information” file, “Outputs” section (example)
1
Output Q1 (see figure 19, page 29)
2
Output Q2
3
Output Q3, configured via “Contamination output (Alarm)” function (see figure 19, page 29)
4
Analog output QA1 (see figure 21, page 31)
5
Analog output QA2 (see figure 21, page 31)
6
Off delay (see figure 22, page 32)
7
Hysteresis cannot be set in SOPAS ET
8
The number of beams as of which the contamination signaling alarm is active (see figure 24, page 33)
9
“/” is used to identify an inverted output
7 CONFIGURATION
28
T E C H N I C A L I N F O R M A T I O N | The MLG-2 as a replacement product for the MLG-1 and XLG 8020351.ZLW3/2017-05-03 | SICK