3 SYSTEM DESCRIPTION
18
8023994-17I6/2020-03-19|SICK
ORIGINAL OPERATING INSTRUCTIONS| VMS4100/5100
Subject to change without notice
3.2.4 Cabinet
Fig. 6: SIC2000 cabinet
Legend
1 Air inlet for cooling (with filter mat and cooler)
2 SIM2000 system controller (with alibi memory on the VMS5100)
3 Terminals for voltage supply IN (100–264 V AC / 50–60 Hz)
4 Air outlet for cooling (with filter mat)
5 Power supply unit for supplying voltage to the SIM2000 and 2D LiDAR
sensors
6 Terminals (24 V DC) and fuse module OUT
7 Power supply unit for voltage supply to LFT display (VMS5100 only)
Contains power supply units for the central voltage supply to system components.
Contains the SIM2000 system controller, the central processing and control unit of the
VMS4100/5100.
The SIM2000 system controller contains the legally relevant memory (alibi memory).
Central power supply for all system components.
Coordinates all connected sensors and processes the measured values received.
The SIM2000 system controller receives the measuring points from the 2D LiDAR
sensor and uses the 2D sections to calculate a three-dimensional model.
Determines the box volume and dimensional values based on the calculated 3D model.
The data is sent to the higher-level customer system via the system controller in a host
telegram with a defined format.
NOTE! In the case of the VMS5100, the measurement results are saved in the
SIM2000 alibi memory, which is required for legal-for-trade verification.