EasyManua.ls Logo

Siemens ADVIA 1800 - ISE Parameter Settings window**; Reflex Test Settings window*

Siemens ADVIA 1800
222 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System Overview 63
ISE Parameter Settings window**
Use this window to set the analysis parameters for ISE measurement of Na, Cl, and K
electrolytes.
Perform any of the following tasks at this window:
enter settings for individual electrolytes (Na, Cl, and K)
enter settings for all electrolytes
check CTT settings
Reflex Test Settings window*
Use this window to define reflex testing for reagent methods. You can define up to three
reflex tests for any given test method based on a set of user defined conditions. When all
conditions are true, the specified reflex tests are added to a sample workorder. The system
tracks the workorder as a pending rerun until the reflex tests are completed. Reflex tests
display in the Prev. val. column in the Review/Edit window.
NOTE: When a third result is generated, the second result does not populate the Prev. Gen.
column.
To define reflex testing for a given method, you must list the reagent in the System Test
List window.
Print Form Settings window**
Use this window to design or edit a print form for sample results. When you print reports
from the Print Report or the Review/Edit window, you will select a print form created here.
There are two sample report formats provided:
A Patient Chart report (Chart.frm) is formatted for a single sample.
A Consolidated report (Consolid.frm) is formatted for multiple samples.
You create or edit each print form by placing design elements, such as free-text, sample
attributes, and result data (for example, test name, result value, and flags) on a form page
that has the same dimensions and orientation as the printed page. A grid overlays the form
page. This helps you to position precisely the design elements.
Perform any of the following tasks at this window:
start a new print form or open an existing one
create or edit a print form
view the print preview
print the print form
Ctrl/Cal Sample Setup window*
Perform any of the following tasks at this window:
get or view measurement times, container types and comments for control and
calibration samples
The settings are available in the Calibration Setup, QC Sample Definition, and ISE
Parameter Settings windows for entering sample tray information.
determine the tests set to run on a given position.

Table of Contents

Related product manuals