EasyManua.ls Logo

Siemens SENTRON ATC6300 User Manual

Siemens SENTRON ATC6300
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Manual
3KC ATC6300
Transfer Control Device
Monitoring Devices
03/2018Edition
SENTRON
siemens.com/3KC

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Siemens SENTRON ATC6300 and is the answer not in the manual?

Siemens SENTRON ATC6300 Specifications

General IconGeneral
MountingDIN Rail
Accuracy class0.5
CommunicationModbus RTU
DisplayLCD
Protection classIP20
Rated voltage690 V
Secondary current5 A
Frequency range50 Hz to 60 Hz
Operating temperature range-25°C to +70°C
Storage temperature range-40°C to +70°C

Summary

Introduction to the ATC6300

About this documentation

Details the manual's purpose, scope, required knowledge, and target audience for the ATC6300 device.

Product-specific information

Provides information on ATC6300 certification, reference documents, and technical support resources.

General Information on the ATC6300

Properties of the ATC6300 Transfer Control Device

Outlines the device's features, technical functions, metering capabilities, and application areas.

Compatible Siemens SENTRON Switching Devices

Lists Siemens products compatible with the ATC6300 for transfer switching applications.

Applications of the ATC6300

Transfer Control

Explains transfer control concepts and classes (PC, CB) for switching equipment.

Controlling the Switching Devices

Details how the ATC6300 controls circuit breakers, transfer switching equipment, and contactors.

Voltage Control

Illustrates voltage measurement and control achieved by the ATC6300.

Product Description

Product Overview and User Interface

Describes the ATC6300's physical layout, including the user interface, keys, and QR code.

Menu Navigation

Explains how to navigate the ATC6300's front-mounted LCD menu system.

Display Pages Overview

Details various display pages available on the ATC6300 for monitoring status and data.

Functions of the ATC6300

Basic Functions

Covers fundamental operations like setting the real-time clock and basic device settings.

Password Protection

Explains how to set up and use passwords for physical and remote access.

Alarms Management

Details the ATC6300's alarm system, properties, descriptions, and user-defined alarms.

Automatic Test Function

Describes how to enable, disable, and configure the automatic periodic test for generators.

Extended Functions

Covers advanced features like remote variables, user limits, and counters.

Installation of the ATC6300

Dimensions for Door Cutout

Specifies the required dimensions for mounting the ATC6300 in a control panel door.

ATC6300 Installation Procedure

Provides step-by-step instructions for physically installing the ATC6300 device.

Connection of the ATC6300

General Connection Drawings

Illustrates various connection diagrams for different switching devices and power supplies.

Power Supply Connection

Details methods for connecting AC and DC power supplies to the ATC6300.

Connection of Siemens SENTRON Switching Devices

Provides guidance on connecting various Siemens circuit breakers and switching equipment.

Operation of the ATC6300

Operating Modes

Describes the ATC6300's three operating modes: OFF, Manual, and Automatic.

Designation and Description of Inputs

Details the ATC6300's digital inputs, their functions, and addressing.

Designation and Description of Outputs

Details the ATC6300's digital outputs, their functions, and configuration options.

Parameterization of the ATC6300

Parameterization via User Interface

Explains how to configure ATC6300 parameters using the device's front panel interface.

Parameterization via powerconfig Software

Guides on configuring the ATC6300 using Siemens powerconfig software.

Parameters Overview

Lists and describes all settable parameters (P01-P15) for the ATC6300 device.

P05 - Changeover Parameters

Details parameters related to load changeover settings and conditions for the ATC6300.

P08 - Communication Parameters

Configures communication settings for MODBUS TCP/RTU via expansion modules.

Commissioning the ATC6300

Commissioning Procedure

Provides a step-by-step guide for the initial setup and commissioning of the ATC6300.

MODBUS Communication

General Information on MODBUS

Introduces MODBUS protocols (RTU, TCP, ASCII) supported by the ATC6300 via expansion modules.

MODBUS Functions

Explains available MODBUS functions for reading, writing, and status queries.

Data Library for MODBUS

Lists register addresses for measured values, status bits, commands, and alarms.

Changing Parameters via MODBUS

Details the process for modifying ATC6300 parameters using MODBUS commands.

Accessories for the ATC6300

Expansion Modules

Lists available expansion modules for digital I/O and communication interfaces.

Expansion Module 4DI

Details the 4DI expansion module (3KC9000-8TL60) including its specifications.

Technical Specifications for Expansion Modules

Provides technical details for various expansion modules like 4DI, 4DO, 2DI2DO, 2DO.

Cover Frame

Describes the cover frame (3KC9000-8TL67) for front-panel IP65 protection.

USB Front Interface

Explains the USB front interface (3KC9000-8TL73) for parameterization and its requirements.

Technical Specifications

Auxiliary Power Supply Specifications

Details voltage, range, frequency, and power consumption for auxiliary power supply.

Connections and Wiring

Covers terminal connections, cable cross-sections, and tightening torques.

Certifications and Approvals

Lists standards and approvals complied with by the ATC6300 and its components.

Dimension Drawings

ATC6300 Dimensions

Provides dimensional drawings for the main ATC6300 unit.

Expansion Module Dimensions

Shows dimensional drawings for various DI DO, RS485, and Ethernet expansion modules.