EasyManuals Logo

Siemens SIMATIC S7-300 Module data Function Manual

Siemens SIMATIC S7-300 Module data
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #103 background imageLoading...
Page #103 background image
03/2013 3 Setting up functions
3.2 Configuring measurements and measurement series
© Siemens AG 2006-2013 All Rights Reserved
SINUMERIK Integrate AMB, AMC, AMM, Function Manual (FH) - 03/2013
3-103
3.2 Configuring measurements and measurement series
Function description
Configuration of measurements and measurement series it when you define the
parameters required for measurement. The configurations created are always
stored with the measurements and can be used again to repeat the measurements.
That especially applies to measurement series. The configuration of a
measurement series ensures that measurements are made with the same settings
every time. This permits evaluation of the progression of characteristics over time.
In addition to parameters for performing a measurement, the limit values of the
characteristics are also configured. Limit values can be configured for
measurement series. The configuration is only possible on the PC. Individual
measurements that do not belong to a measurement series cannot have limit
values.
Availability and privileges
On the operator panel, a measurement is configured or a measurement series
configuration changed only during the measurement procedure. On the operator
panel, it is only possible to create a measurement series based on a measurement
being performed.
On the PC, it is possible to configure measurement series. The authorization
required to configure measurements and measurement series is described in detail
in the Appendix.

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)