3 Setting up functions 03/2013
3.4 Fault services
© Siemens AG 2006-2013 All Rights Reserved
3-114 SINUMERIK Integrate AMB, AMC, AMM, Function Manual (FH) - 03/2013
3.4 Fault services
3.4.1 Control monitors - List view
Function description
Events occurring directly in the control, or even as a result of evaluations of control
values or a machine operator's activities, can be evaluated by control monitors.
As a result, machine statuses can be acquired in order to draw general conclusions
about errors (e.g. alarms), current machine states (e.g. about accuracy determined
by circularity test), or use of resources; to collect production data (e.g. workpiece
counters); to obtain statistical data; and to analyze individual events on a
temporary basis.
Machine operators can use a control monitor to determine which signals they are
interested in and, therefore, which automatic tasks they wish to trigger. When the
SINUMERIK Integrate system detects such an event, it can automatically trigger
actions which, in turn, trigger specific operating sequences or provide diagnostics
data for further analysis.
Fig. 3-21: Control monitors - List view
Note
To define the data that is to be created and the actions that are to be initiated by
a given signal or a combination of signals from a machine at a given predefined
state in the server, the machine operator creates one or more control monitors.

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)

Related product manuals