1 Introduction ................................................................................................. 1-9
1.1 Overview of the SINUMERIK Integrate documentation............................. 1-9
1.2 Overview of functions ................................................................................ 1-10
1.3 Operating Concept..................................................................................... 1-12
2 Machine information................................................................................... 2-19
2.1 Machine overview ...................................................................................... 2-19
2.1.1 Current control software ......................................................................... 2-20
2.1.2 Machine events - List view...................................................................... 2-21
2.1.3 Machine events - Detailed view.............................................................. 2-24
2.1.4 Evaluation of workflow actions................................................................ 2-26
2.1.5 Evaluation of diagnostics data................................................................ 2-27
2.2 Variable monitors – time Series – measurements and
measurement series ............................................................................... 2-39
2.2.1 Visualization on the Internet PC ............................................................. 2-39
2.2.2 Operating diagrams ................................................................................ 2-41
2.2.3 Control elements of the diagrams for individual measurements ............ 2-46
2.2.4 Circularity test ......................................................................................... 2-48
2.2.5 Equability test.......................................................................................... 2-49
2.2.6 Universal axis test................................................................................... 2-51
2.2.7 Variable monitors.................................................................................... 2-52
2.2.8 Deleting measurements and data points ................................................ 2-55
2.3 Test series on the machine........................................................................ 2-58
2.3.1 Performing measurement series............................................................. 2-58
2.3.2 Test requirements................................................................................... 2-59
2.3.3 Prolog and epilog program for a measurement...................................... 2-61
2.3.4 Program example ................................................................................... 2-65
2.3.5 Measurement commissioning................................................................. 2-68
2.3.6 Release protocol between PLC and SINUMERIK Integrate................... 2-69
2.3.7 Contour test ............................................................................................ 2-69
2.4 Archives ..................................................................................................... 2-71
2.5 Maintenance .............................................................................................. 2-80
2.6 Remote access .......................................................................................... 2-85
3 Setting up functions ................................................................................... 3-87
3.1 Maintenance .............................................................................................. 3-89
3.1.1 Creating maintenance schedules ........................................................... 3-89
3.1.2 Configuring variable monitors................................................................. 3-94

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)