Glossary
S7-300 Automation System Module data
Glossary-4 Manual, 08/2006, A5E00105505-04
electrically interconnected
The reference potential of the control and load voltage circuits of non-isolated IO modules
are electrically interconnected.
FREEZE
STEP 7 parameter for the SM 338; POS-INPUT position detection module. FREEZE is a
control command (function), used to freeze actual encoder values of SM 338.
Ground
The conductive earth whose electrical potential can be set equal to zero at any point.
Ground potential may be different from zero in the area of grounding electrodes. The term
"reference ground" is frequently used to describe this situation.
grounding
Grounding means, to connect an electrically conductive component via an equipotential
grounding system to a grounding electrode (one or several conductive components with low
impedance contact to earth.)
Hardware interrupt
Function initiated by interrupt-triggering modules, based on specific events in the process
(high or low limit violated, module has completed cyclic conversion of channels.)
The hardware interrupt is reported to the CPU, The CPU executes the assigned →
Organization block according to interrupt priority.
Hold last value (HLV)
The module retains the last value output before the CPU went into STOP.
Input delay
STEP 7 parameter for digital input modules. The input delay function is used to suppress
coupled disturbance. This includes pulse-shaped disturbance within the range from 0 ms to
the set input delay
The input delay tolerance is defined in the technical data of the module. The length of
suppressed pulse-shaped disturbance is determined by the length of the input delay.
The permissible input delay is determined by the line length between the encoder and the
module. Unshielded encoder supply lines of a grater length (more than 100 m) require a long
delay setting.
Integration time
STEP 7 parameter for analog input modules. The integration time is equivalent to the inverse
value of the → noise suppression frequency in ms.

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)

Related product manuals