Glossary
S7-300 Automation System Module data
Manual, 08/2006, A5E00105505-04
Glossary-5
Interface, multi-point
→ MPI
Interrupt
SIMATIC S7 knows 28 different priority classes which control user program execution. Those
priority classes also include hardware interrupts, for example. When an interrupt is
generated, the operating system automatically calls an assigned OB which the user can
program to trigger a specific action (at an FB for example.)
Interrupt, diagnostics
Diagnostics interrupt
Interrupt, end of cycle
→ hardware interrupt
Interrupt, hardware
→ hardware interrupt
Linearity error
Denotes the maximum deviation of the measured/output value from the ideal linear
relationship between the measured/output signal and the digital value. Defined as a
percentage, relative to the rated range of the analog module.
Logic block
A SIMATIC S7 logic block contains elements of the
STEP 7
user program. In contrast, a
data block only contains data. Available logic blocks: Organization Blocks (OBs), Function
Blocks (FBs), Functions (FCs), System Function Blocks (SFBs), System Functions (SFCs).
Measuring range module
Modules installed on analog input modules for the adaptation to different measuring ranges.
Mode of operation
Definition of this term:
1. selection of a CPU operating state using the mode selector switch or a PG
2. the type of program execution at the CPU
3. an analog input module parameter in
STEP 7

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)

Related product manuals