Configuration
5.2 Configuring workflow
1FW3 complete torque motors
94 Configuration Manual, 08/2020, A5E46027705B AA
5.2.2 Define the supplementary conditions and integrate the drive into the automation
system
If high maximum speeds are to be reached, then induction motors can be used in the field
weakening range. Induction motors are also suitable for higher power ratings.
The drives should either be defined as single-axis drives or in a group as multi-axis drives.
When engineering the system, the motor utilization according to rated values for winding
temperature rise 60 K or 100 K should be taken into account.
Other supplementary conditions apply when integrating the drives into an automation
environment such as SIMATIC or SIMOTION.
For motion control and technology functions (e.g. positioning), as well as for synchronous
operation functions, the corresponding automation system, e.g. SIMOTION D, is used.
The drives are interfaced to the higher-level automation system via PROFIBUS.