Electrical connection
8.3 System integration
1FW3 complete torque motors
Configuration Manual, 08/2020, A5E46027705B AA
311
8.3.4 Rotating the connector at the motor
Signal connector and integrated Sensor Module can be rotated to a limited extent.
Note
Observe the following when rotating the connectors:
Do not exceed the permissible range of rotation.
In order to maintain the degree of protection, max. 10 rotations are permissible.
Keep to the maximum rotating torque. See Table "Maximum rotating torques that occur".
Only rotate the connector with a mating connector that matches the connector thread.
Secure the connection cables against tensile and bending stress.
Secure the connector against rotating further.
It is not permissible to subject the connector to continuous forces.
Table 8- 5 Maximum rotating torques that occur
Connector
Max. rotating torques that occur [Nm]
Signal connector
8
Integrated Sensor Module
8
Signal cable
The manufacturer mounts the plug-in connection for the signal cable (at the encoder terminal
box).
When connecting the connector, insert the coding groove into the socket connector until it
is flush and tighten the screw cap by hand as far as it will go.