Installation
4.2 Electrical Installation
Cable, connectors and tools specifications
The detailed specifications for the cables, connectors and tools required to manufacture the
necessary cables for the SINAMICS G120D are listed in the following tables. The
connections that are detailed in this section relate to the physical connections that exist on
the Inverter. Information for the preparation and construction of the individual connectors
have separate detailed instructions delivered with the ordered parts, direct from the
manufacturers. Use 75 °C copper wire only.
Note
NFPA compatibility
These devices are intended only for installation on industrial machines in accordance with
the "Electrical Standard for Industrial Machinery" (NFPA79). Du
e to the nature of these
devices they may not be suitable for installation accordance with the "National Electrical
Code" (NFPA70).
Table 4- 9 Tools
Crimp tool (Q8/0 and Q4/2)
Harting part number 0999-000-0305
No special tools are required for the Control Unit connectors
Table 4- 10 Control unit connectors
24 V DC power supply In
6GK1905-0FB00 3RK1902-3DA00
24 V DC power supply Out
6GK1905-0FA00 3RK1902-3BA00
PROFINET P
(M12)
6GK1901-0DB20-6AA0 3RK1902-2DA00
Encoder (M12 ) Via KnorrTec: Knorrtec
(
http://www.knorrtec.de/index.php/en/company-profile/siemens-
Digital input and output,
analog input (M12 )
3RK1902-4BA00-5AA0 3RK1902-4DA00-5AA0
Converter with control units CU240D-2
46 Operating Instructions, 04/2015, FW V4.7.3, A5E34262100B AB