The maximum cable length that can be connected is 30 m.
Note
The two "+" or "M" terminals are jumpered in the connector. This ensures that the supply
voltage is looped through.
Note
The terminal block must be screwed on tightly using a flat-bladed screwdriver.
3.1.2.6 X127 LAN (Ethernet)
Note
Application
Ethernet interface X127 is intended for commissioning and diagnostics, which means that it
must always be accessible (e.g. for service).
Furthermore, the following restrictions apply to X127:
Only local access is permissible
No networking - or only local networking is permissible in a locked control cabinet
If remote access to the control cabinet is required, then additional security measures must be
taken to prevent misuse through sabotage, unqualified data manipulation and intercepting
confidential data (see also the Chapter "Industrial Security").
Table 3-6 X127 LAN interface (Ethernet)
Pin Signal name Technical data
1 TXP Ethernet transmit data +
2 TXN Ethernet transmit data -
3 RXP Ethernet receive data +
4 Reserved, do not use -
5 Reserved, do not use -
6 RXN Ethernet receive data -
7 Reserved, do not use -
8 Reserved, do not use -
Connector type: RJ45 socket
Note
The LAN interface does not support auto-MDI(X). If the LAN interface of the communication
partner also cannot handle auto-MDI(X), then a crossover cable must be used to establish the
connection.
Control Units
3.1 Control Unit CU320-2 PN (PROFINET)
Supplementary component descriptions
Manual, 06/2019 19