PE conductor connection
M4 / 1.8 Nm
Neutral point grounding
Connector jumper
X530
Figure 6-2 X530 interface at the VSM10 (view from below)
6.2.2 X500 DRIVE-CLiQ interface
Table 6-2 X500: DRIVE-CLiQ interface
Pin Signal name Technical data
1 TXP Transmit data +
2 TXN Transmit data -
3 RXP Receive data +
4 Reserved, do not use -
5 Reserved, do not use -
6 RXN Receive data -
7 Reserved, do not use -
8 Reserved, do not use -
A + (24 V) Power supply
B M (0 V) Electronics ground
Connector
type
DRIVE-CLiQ socket
The blanking cover for the DRIVE-CLiQ port is included in the scope of delivery.
Blanking covers (50 x) Article No.: 6SL3066-4CA00-0AA0
Voltage Sensing Module VSM10