11
Oscillation 08.97
11.1 As
nchronous oscillation
11
840D
NCU 571
840D
NCU 572
NCU 573
FM-NC 810D 840Di
ï›™
Siemens AG 2000. All rights reserved
11-400
SINUMERIK 840D/840Di/810D/FM-NC Programming Guide Advanced (PGA) – 04.00 Edition
This timing is affected by the feedrate
override.
Under certain circumstances, an oscillating stroke is
performed before the spark out strokes are started
or the end position approached.
The impression created is that the deactivation
response changes. However, this is not the case.
Setting feed FA
The feedrate is the defined feedrate of the
positioning axis.
If no feedrate is defined, the value stored in the
machine data applies.
Defining the sequence of motions: OSCTRL
The control settings for the movement are set with
enable and reset options.
Reset options
These options are deactivated (only if they have
previously been activated as setting options).
Set options
These options are switched over. When OSE (end
position) is programmed, option 4 is implicitly
activated.