Appendix
A.9 Information List
SIPROTEC, 7SK80, Manual
E50417-G1140-C344-A4, Release date 08.2010
465
10032 Total Motor Stopped Time (Motor
Stop.Time)
Mot.Statistics VI
10033 Motor Percent Running Time
(Perc.Run.Time)
Mot.Statistics VI
10034 50-3 BLOCKED (50-3
BLOCKED)
50/51 Overcur. OUT On
Off
On
Off
* LED BO 60 169 1 Yes
10035 50N-3 BLOCKED (50N-3
BLOCKED)
50/51 Overcur. OUT On
Off
On
Off
* LED BO 60 170 1 Yes
10036 Malparameteriz. Volt.-divider Ca-
pacities (Capac.Par.Fail.)
P.System Data 1 OUT On
Off
LED BO
10037 Startup Duration 2 (Dur.) Mot.Statistics VI
10038 Startup Current 2 (Cur.) Mot.Statistics VI
10039 Startup Voltage 2 (Volt.) Mot.Statistics VI
10040 Startup Duration 3 (Dur.) Mot.Statistics VI
10041 Startup Current 3 (Cur.) Mot.Statistics VI
10042 Startup Voltage 3 (Volt.) Mot.Statistics VI
10043 Startup Duration 4 (Dur.) Mot.Statistics VI
10044 Startup Current 4 (Cur.) Mot.Statistics VI
10045 Startup Voltage 4 (Volt.) Mot.Statistics VI
10046 Startup Duration 5 (Dur.) Mot.Statistics VI
10047 Startup Current 5 (Cur.) Mot.Statistics VI
10048 Startup Voltage 5 (Volt.) Mot.Statistics VI
10080 Error Extension I/O (Error Ext I/O) Device, General OUT On
Off
**LEDBO
10081 Error Ethernet (Error Ethernet) Device, General OUT On
Off
**LEDBO
10082 Error Current Terminal (Error Ter-
minal)
Device, General OUT On
Off
**LEDBO
10083 Error Basic I/O (Error Basic I/O) Device, General OUT On
Off
**LEDBO
14101 Fail: RTD (broken wire/shorted)
(Fail: RTD)
RTD-Box OUT On
Off
**LEDBO
14111 Fail: RTD 1 (broken wire/shorted)
(Fail: RTD 1)
RTD-Box OUT On
Off
**LEDBO
14112 RTD 1 Temperature stage 1
picked up (RTD 1 St.1 p.up)
RTD-Box OUT On
Off
**LEDBO
14113 RTD 1 Temperature stage 2
picked up (RTD 1 St.2 p.up)
RTD-Box OUT On
Off
**LEDBO
14121 Fail: RTD 2 (broken wire/shorted)
(Fail: RTD 2)
RTD-Box OUT On
Off
**LEDBO
14122 RTD 2 Temperature stage 1
picked up (RTD 2 St.1 p.up)
RTD-Box OUT On
Off
**LEDBO
14123 RTD 2 Temperature stage 2
picked up (RTD 2 St.2 p.up)
RTD-Box OUT On
Off
**LEDBO
14131 Fail: RTD 3 (broken wire/shorted)
(Fail: RTD 3)
RTD-Box OUT On
Off
**LEDBO
14132 RTD 3 Temperature stage 1
picked up (RTD 3 St.1 p.up)
RTD-Box OUT On
Off
**LEDBO
14133 RTD 3 Temperature stage 2
picked up (RTD 3 St.2 p.up)
RTD-Box OUT On
Off
**LEDBO
14141 Fail: RTD 4 (broken wire/shorted)
(Fail: RTD 4)
RTD-Box OUT On
Off
**LEDBO
14142 RTD 4 Temperature stage 1
picked up (RTD 4 St.1 p.up)
RTD-Box OUT On
Off
**LEDBO
No. Description Function Type
of In-
for-
matio
n
Log Buffers Configurable in Matrix IEC 60870-5-103
Event Log ON/OFF
Trip (Fault) Log ON/OFF
Ground Fault Log ON/OFF
Marked in Oscill. Record
LED
Binary Input
Function Key
Relay
Chatter Suppression
Type
Information Number
Data Unit
General Interrogation