1.3 Characteristics
25
7UT613/63x Manual
C53000-G1176-C160-2
• Instantaneous tripping possible at any stage when closing onto a short-circuit
• Inrush restraint using the second harmonic of the measured current
• Dynamic switchover of the time overcurrent protection settings, e.g. during cold-
load start-up of the power plant
• 3 time overcurrent protection functions for phase currents and residual current
Time Overcurrent
Protection for Earth
Current
• Two definite time delayed overcurrent stages for the earth current, e.g. current
between starpoint and earth
• Additionally, one inverse time delayed overcurrent stage for the earth current
• Selection of various inverse time characteristics of different standards is possible,
alternatively a user defined characteristic can be specified
• The three can be combined as desired
• External blocking facility for any desired stage (e.g. for reverse interlocking)
• Instantaneous trip when switching on a dead fault with any desired stage
• Inrush restraint function with 2nd harmonic
• Dynamic switchover of the time overcurrent parameters, e.g. during cold-loaded
start-up of the power plant
• 2 time overcurrent protection functions are possible for earth current
1-phase Overcur-
rent Protection
• Two definite time delayed overcurrent stages which can be combined as desired
• For any 1-phase overcurrent detection
• Can be assigned to the „normal “1-phase current input or to the highly sensitive
current input
• Suitable for detection of very small current (e.g. for high-impedance unit protection
or tank leakage protection)
• Suitable for detection of any desired AC voltage using an external series resistor
(e.g. for high-impedance unit protection)
• External blocking facility for any stage
Unbalanced Load
Protection
• Evaluation of the negative sequence system of the three phase currents of any
desired side of the protected object or any three-phase measuring point
• Two definite time delayed negative sequence current stages and one additional
inverse time delayed negative sequence current stage
• Selection of various inverse time characteristics of different standards is possible,
alternatively a user defined characteristic can be specified
• The stages can be combined as desired.
• Trip blocking on detection of broken wire
• Thermal characteristic with adjustable negative sequence factor and adjustable
cooldown time.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIPROTEC 7UT613 series and is the answer not in the manual?

Siemens SIPROTEC 7UT613 series Specifications

General IconGeneral
BrandSiemens
ModelSIPROTEC 7UT613 series
CategoryProtection Device
LanguageEnglish

Related product manuals