1 Introduction
26
7UT613/63x Manual
C53000-G1176-C160-2
Thermal Overload
Protection
• Thermal replica of current-initiated heat losses
• True RMS current calculation
• Can be assigned to any desired side of the protective object
• Adjustable thermal warning stage
• Adjustable current warning stage
• With or without including the ambient or coolant temperature (by means of external
resistance temperature detector via RTD-box)
• Alternative evaluation of the hot-spot temperature according to IEC 60354 with cal-
culation of the reserve power and ageing rate (by means of external resistance tem-
perature detector via RTD-box)
• 2 breaker failure protection functions possible
Overexcitation Pro-
tection (device with
voltage measure-
ment inputs)
• Processing of the voltage/frequency ration U/f, which represents the induction B of
a shunt reactance (transformer, shunt reactor)
• Adjustable warning and tripping stage (with independent delay time)
• Inverse standard characteristic or user-defined trip characteristic for calculation of
the thermal stress, selectable
Reverse Power Pro-
tection (Device with
Voltage Measure-
ment Inputs)
• Real power calculation from positive sequence components
• Short operating time or exact calculation of the active power via 16 cycles
• Exact real power calculation for small power factor by compensating the error angle
of the measuring locations
• Insensitive to power fluctuations
• Short-time stage with external criteria, e.g. with closed emergency tripping
Forward Power
Monitoring (devic-
es with measuring
voltage inputs)
• Real power calculation from positive sequence components
• Supervision of overvoltage (P>) or undervoltage (P<) of power with individually ad-
justable power limits
• Short operating time or exact calculation of the active power via 16 cycles
• Automatic blocking of stage P< for recognised measured voltage failure or wire
break in CT secondary circuit
Undervoltage Pro-
tection (Device with
Voltage Measure-
ment Inputs)
• Two-stage three-phase undervoltage measurement
• Evaluation of positive sequence component of the connected voltages, therefore in-
dependent of asymmetries
• Automatic blocking for measuring voltage failure
• Adjustable dropout ratio
Overvoltage Pro-
tection (Device with
Voltage Measure-
ment Inputs)
• Two-stage three-phase overvoltage measurement
• Evaluation of the largest of the three phase-to-ground voltages or the largest of the
three phase-to-phase voltages (largest of the three phase-to-phase voltages (can
be set)
• Adjustable dropout ratio

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIPROTEC 7UT613 series and is the answer not in the manual?

Siemens SIPROTEC 7UT613 series Specifications

General IconGeneral
BrandSiemens
ModelSIPROTEC 7UT613 series
CategoryProtection Device
LanguageEnglish

Related product manuals