3.2.4 Installing SITRANS MS200 on a gear
Mount SITRANS MS200 directly on the gear. The most suitable place is at the middle of the gear
in the horizontal position.
NOTICE
Maximum specied ambient temperature
The maximum specied ambient temperature must not be exceeded by the gear. See Technical
specications SITRANS MS200 (Page65).
Note
SITRANS MS200 must not get in contact with gear oil or gear oil vapors.
3.2.5 Installing SITRANS MS200 on rotating or vibrating equipment
Any rotating or vibrating equipment can be supervised with SITRANS MS200. Mount SITRANS
MS200 as close as possible to vibrating components.
NOTICE
Maximum specied ambient temperature
The maximum specied ambient temperature must not be exceeded by the rotating or
vibrating equipment. See Technical specications SITRANS MS200 (Page65).
3.3 Disassembly SITRANS MS200
WARNING
Incorrect disassembly
In order to disassemble correctly, observe the following:
• Before starting work, make sure that you have switched o all physical variables such as
pressure, temperature, electricity etc. or that they have a harmless value.
• Make sure that no environmentally hazardous media are released.
• Secure the remaining connections so that no damage can result if the process is started
unintentionally.
Installing/mounting
3.3Disassembly SITRANS MS200
SITRANS CC220 and SITRANS MS200
38 Compact Operating Instructions, 10/2023 - DRAFT, A5E...-AA