10.Put the battery holder cap back on. Ensure that the battery holder cap is correctly snapped
in.
11.Connect the battery connector .
⇒ The LED placed on the PCBA lights up for one second.
12.Place the lid on SITRANS MS200 and screw it on to 6-7 Nm per hand.
SITRANS MS200 is now active again.
6.3.3 Replacing SITRANS MS200
WARNING
Humid environment
If working on an energized device is necessary, ensure that the environment is dry.
Make sure when carrying out cleaning and maintenance work that no moisture penetrates
the inside of the device.
CAUTION
Hot surfaces
Risk of burns during maintenance work on parts having surface temperatures exceeding 65 °C
(149°F).
Take corresponding protective measures, for example by wearing protective gloves.
After carrying out maintenance, remount touch protection measures.
Replacing a defective SITRANSMS200
1. Stop anomaly detection models of the respective SITRANSMS200.
2. Replace defective SITRANSMS200 with new SITRANSMS200.
3. Make sure new SITRANSMS200 is powered up.
4. Disconnect defective SITRANSMS200 in SITRANSSCMIQ.
5. Connect new SITRANSMS200 with SITRANSSCMIQ and assign sensor to existing
MindSphere asset.
For detailed description see AUTOHOTSPOT.
6. Train new anomaly detection model based on new SITRANSMS200 data.
Repositioning SITRANSMS200 on the same machine
Note
In this scenario SITRANS CC220 and MindSphere asset remain the same.
Service and maintenance
6.3Maintenance and repair work for SITRANS MS200
SITRANS CC220 and SITRANS MS200
56 Compact Operating Instructions, 10/2023 - DRAFT, A5E...-AA