19
SC213 Diesel Engines
DAILY OR EVERY 8 HOURS WHICHEVER
OCCURS FIRST:
Keep Engine Clean.
Check level of coolant.
Check oil level in sump.
Check oil pressure.
Check for water in the fuel filter.
EVERY 250 HOURS OR 12 MONTHS:
Drain and renew lubricating oil.
Renew lubricating oil filter (canister).
Check drive belt tension.
Clean and Renew lubricating oil from wet type air cleaner.
Clean fuel lift pump pre-filter (where fitted).
Check engine for leakage of oil and water.
EVERY 500 HOURS OR TWO YEARS.
Check hoses and clips.
Check atomisers.
Check valve tip clearances.
Examine valve springs.
Inspect valve rocker shaft assembly for lubrication.
Clean and treat battery terminals.
Replace fuel filter element. (Spin on type).
EVERY 1,000 HOURS:
Drain fuel tank, remove and clean.
Flush radiator with clean water.
DRY TYPE AIR CLEANER MAINTENANCE
In extreme dust condition clean the air cleaner daily.
Check Air restriction indicator in air cleaner (when engine
is running).
1st Cleaning after 100 Hrs.
2nd cleaning after 200 Hrs.
Discard the element if found complete choked.
Main Outer Element can be cleaned twice only with
pressurised air (applying from inside to outside) before
replacement.
Safety cartridge/ inner element is to be replaced along
with the third fitment of Main outer Element.
Remove the dust every after 50 Hrs. from dust unloader
by press opening the lip.
Note : The interval of cleaning the air cleaner element
depends on operating conditions; therefore under
extremely dusty conditions, the time interval to be
shortened.
The correct maintenance of the air cleaner will help in
extend the life of the engine.
FUEL FILTERS MAINTENANCE
(Make: BOSCH , India)
Do not clean filter canister.
Drain filter bowls after every 125 hrs. of operation by
loosening sludge screws (wherever provided), until clean
fuel flows out.
Fuel filter single canister type spin on element should be
replaced after every 500 hours of operation.
Section E