3. Overview/functional description
3
- 25 -
951-230-008-EN
Version 04
Lubricant
inlet
6a
5a
6
3a
2a
1a
4
4a
3
1
6
5
2
left/front
right/front
left/backright/back
right/back left/back
6a
5a
6
3a
2a
1a
4
4a
3
1
5
2
6
left/front
right/front
right/back left/back
Piston lobe 4 is under pump pressure; piston lobe 1 has dis-
charged to outlet 1a. The connection of main line to piston lobe 5
has been released due to movement of piston 1/4.
Piston lobe 5 has been actuated and piston lobe 2 delivers
via outlet 2a. Piston lobe 6 is actuated next, etc.
Fig. 6 Sectional view