11. Malfunctions
11
11.2 Progressive metering device and system malfunctions
Malfunction Cause Remedy
No lubricant at
lubrication points
o Main metering device or secondary metering device is defective
- Can be detected if no grease can be pressed through the distribu-
tor after removing all union nuts or fittings at the outlets.
o Check the flow in the main metering device and secondary meter-
ing device
- Sequentially remove union nuts or fittings at the outlets; check
valves may be built into the outlet fittings.
- Trigger intermediate lubrication.
- The progressive metering device is functioning properly if signifi-
cant grease discharge is seen at all outlets.
- Replace the progressive metering device if grease does not dis-
charge at all outlets.
Note!
The metering and arrangement of sections on the new progressive
metering device must be identical to the disassembled (defective)
metering device.
Replace the progressive metering device
- Loosen all fittings, mark lines, secure
against outside influences
Install a new progressive metering device
Install lubrication lines in the correct or-
der as marked previously
Only use original SKF spare parts!
Perform start-up and functional
inspection.
o Defective or blocked secondary feed line Detach feed line, identify cause of
blockage, replace secondary feed line if
necessary
- 93 -
951-230-008-EN
Version 04
EN

Table of Contents

Other manuals for SKF VP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SKF VP Series and is the answer not in the manual?

SKF VP Series Specifications

General IconGeneral
BrandSKF
ModelVP Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals