11. Malfunctions
Malfunction Cause Remedy
Insufficient
lubricant
discharge
o Air cushion in main metering de-
vice or secondary metering device
Perform venting on the secondary metering device discharging too little
lubricant.
Grease progressive system - see Chapter 7.2.1
Oil progressive system - see Chapter 7.2.2
No lubricant
at lubrication
points
o Damaged lubricant line, detect-
able only by visual inspection and
significant lubricant discharge.
o Visual inspection
Replace the lubricant line
Use only grease-filled SKF original spare lines on grease progressive systems.
Perform start-up and functional inspection.
Visual inspection for mechanical damage
Pinching and sharp bends are blocking the grease flow
o Check the lubricant supply Check grease supply in the lubricant reservoir, refill if necessary.
Start-up, functional inspection
Trigger interim lubrication.
o Defective lubrication point
o Defective bearing
o Bearing bush twisted
Check bearing for mechanical damage or contamination.
Check bearing for proper function (move the machine and check for.
bearing noise).
Use a high-pressure grease gun to make the bearing move freely. If this is not
possible, the bearing must be repaired or replaced by technical personnel
Install all lines and fittings that were removed during troubleshooting.
Perform start-up and functional inspection.
- 94 -
951-230-008-EN
Version 04
EN

Table of Contents

Other manuals for SKF VP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SKF VP Series and is the answer not in the manual?

SKF VP Series Specifications

General IconGeneral
BrandSKF
ModelVP Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals