11. Malfunctions
11
Malfunction Cause Remedy
System malfunction
o Piston detector on main metering
device has indicated that the system
is not working.
Loosen both lubrication lines on the last metering section of the
main metering device, switch on the lubrication system, and check
whether lubricant discharges without bubbles. If lubricant dis-
charges without bubbles, tighten both lubrication lines and repeat
the procedure on all secondary metering devices, starting from
the closest progressive metering device. Vent the possibly defec-
tive progressive metering device again; replace in the event of
reoccurrence.
If all progressive metering devices function properly, check the
electrical connection of the piston detector and the piston detector
itself for proper function.
No pressure build up in
the main line
o Pressure relief valve does not close Clean or replace pressure relief valve.
Only use original SKF spare parts.
o Unsuitable lubricant (see technical
data)
Remove lubricant from entire system and dispose of lubricant in
the proper manner; fill system with suitable lubricant
o Fill level too low Top up lubricant
o Pump element is defective Inspect pump element and replace if necessary
- 95 -
951-230-008-EN
Version 04
EN

Table of Contents

Other manuals for SKF VP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SKF VP Series and is the answer not in the manual?

SKF VP Series Specifications

General IconGeneral
BrandSKF
ModelVP Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals