8 Operation
SMA Solar Technology AG
Operating manual EVC22-3AC-20-BE-en-10 71
8.6 Configuring the fast stop function
Requirements:
☐ The user interface must be open and you must be logged in.
Procedure:
1. Select the product in the focus navigation.
2. Select the menu Configuration.
3. Select the menu item I/O configurations.
4. Select the type of the I/O channel Digital input.
5. Select the use for the digital input Signal fast stop.
6. Select the source of the digital value.
7. Select the digital input that is to be used as the fast stop.
8. If necessary, activate inversion of the signal.
9. Assign a name to the I/O channel.
10. Click on [Save].
8.7 Backup file
8.7.1 Function and content of the backup file
The backup file is used to transfer configuration information, e.g., when commissioning a
replacement device or when restoring previously saved parameter settings.
The backup file includes the following system and device configuration data for your product:
• Grid management services
• Network
• Energy meter
• SunnyPortal setting
• Self-defined Modbus profiles
• System Password
• User interface login data
• List of connected devices
• Added RFID cards
The following information is not included in the backup file:
• Notifications
• Historic energy and performance values
8.7.2 Creating a Backup File
Requirements:
☐ The user interface must be open and you must be logged in.