12 Troubleshooting
SMA Solar Technology AG
Operating manual EVC22-3AC-20-BE-en-10 85
12 Troubleshooting
12.1 Event messages
12.1.1 Event 1302
Event message:
Waiting for grid voltage
Grid connection installation failure
Check grid and fuses
Explanation:
L or N not connected.
Corrective measures:
Ensure that the line conductors are connected.
Ensure that the miniature circuit breaker is switched on.
Ensure that the AC cable is not damaged and that it is connected correctly.
12.1.2 Event 3701
Event message:
Residual current too high
Explanation:
A DC residual current has been detected between the product and vehicle.
Corrective measures:
Check the user interface of the vehicle for an error message.
Disconnect the product from the vehicle and reconnect to reset the error message.
12.1.3 Event 6112
Event message:
Watchdog reset
Explanation:
A task has not triggered the software watchdog.