Chapter 5 Display and Setting of Various Functions
HRS Series 5.2 Flow Chart of the Operation Screen
5-7
5.3 List of Functions
Function of the product can be set as shown in Table 5.3-1 List of
functions.
Table 5.3-1 List of functions
1 Only for Option D "With electrical conductivity control"
No. Classification Function Outline
Reference
page
Temperature setting Allows change of the set circulating fluid temperture.
Temperature display Displays the circulating fluid temperature.
Pressure display Displays the circulating fluid discharge pressure.
Flow rate display Displays the circulating fluid flow rate as a guide.
Run/Stop Run/stop the product.
Pump independent operation Independently operates the pump.
Operation mode selection
Displays the operation mode.
Selects the operation from touch panel or communication.
Operationg condition display Displays the operating status.
2 Menu Menu display Selects a menu for various settings.
Chapter
5.4.2
3 Status screen Sensor value display Displays the sensor value of the product.
Chapter
5.4.3
4
Information screen Alarm/maintenance display
Displays an alarm name when the alarm goes off.
Displays a maintenance reminder.
Displays previously activated alarms.
Chapter
5.4.4
5
Check operation time screen
Check operation time
Reset operation time
Following operation times can be checked:
The operation time can be reset.
Pump
Compressor
Fan
Time of use of DI filter
Time of use of dustproof filter
Chapter
5.4.5
6
Software version screen Display of software version Software version can be checked.
Chapter
5.4.6
Temperature rise/drop alarm Sets the temperature rise/drop alarm (AL10/AL11).
TEMP READY function Sets TEMP READY signal and alarm (AL12).
TEMP OFFSET Sets the offset mode.
Pump operation mode Sets the pump operation mode and set value.
Discharge pressure rise/drop alarm
Sets the pump discharge pressure rise/drop alarm
(AL19/AL20) and discharge pressure sensor failure (AL18).
Electric conductivity Sets the electric conductivity.*1
KEY LOCK
Prevents operations other than "run/stop", "charge screen" and
"alarm reset".
START-UP Selects the operating method to turn on the power.
ANTI-FREEZE Sets the anti-freezeing operation.
WARMING UP Sets the warming up.
PUMP KEEP RUN Sets the pump continuing operation function.
Ambient temperature alarm
Selects the enabling/disabeing of ambient
temperature alarm (AL35).
Maintenance alarm
Sets the assignment of "maintenance reminder" as an alarm
signal (AL36).
TEMP OUT function setting Sets TEMP OUT function.
Data reset Resets set values to default settings.
Communication alarm
Sets the communication error (AL34) and connect input 1 and 2
signal detection (AL30/AL31).
Serial communication Sets RS-232C and RS-485.
Analogue output Sets the analogue output.
Contact input signal Sets the contact input signal.
Contact output signal Sets the contact output signal.
8
Function setting screen
Chapter
5.4.8
9
Communication setting screen
Chapter
5.4.9
1
Home screen
Chapter
5.4.1
7
Circulating fluid setting screen
Chapter
5.4.7