EasyManua.ls Logo

SMC Networks HRS Series - Replacement of Consumables; Replacing the DI Filter 【For Option D

SMC Networks HRS Series
153 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DOC1001322
Chapter 7 Control, Inspection and Cleaning
HRL Series 7.4 Replacement of consumables
7-9
7.4 Replacement of consumables
7.4.1 Replacing the DI Filter For Option D
Connect DI filter inside this product. In the delivery state,
"Temporary piping for DI filter" is connected. Install the attached
"DI filter" according to the following procedure.
1. Turn off the earth leakage breaker of this product.
2. Remove the maintenance panel. Loosen the 6 fixing screws.
Fig. 7-4 Maintenance panel removal
Before discharging the circulating fluid, stop the users
equipment and release the residual pressure.
Be sure to wear protective shoes and gloves to prevent injury with
the edge of the panel.
Maintenance panel
Screws (6 portions)