Using the P
ump
35
5. V
erif
y
, by looking thr
ough the
cartridge view
ing windo
w
,
that the cartridge is p
ro
p
erly
at
t
ached to the p
ushrod.
Fast
en
the car
tridge cap back ont
o the
pump
. Make sure the rib o
n
the cap lines up with the rib on
the pump
, indic
at
ing the cap is
se
cured (se
e Figure 10).
Figur
e 10
Align
40
42
Table of Contents
Table of Contents
4
Important Information
7
Important Safety Information
7
Warnings
7
Cautions
9
Explanation of Symbols
10
Introduction
12
Indications
12
Contraindications
12
Delivery Features
12
Continuous Rate
12
Doses
12
Other Features
12
Glossary of Terms
13
Programming the Pump
15
Pump Illustrations
15
Description of Features and Buttons
16
Battery Cap with O-Ring
16
Display
16
Programming Keys
16
Demand Dose Button
16
And Keys
16
Cartridge Cap
16
Infrared (IR) Windows
16
Features
17
Vibration Alert
17
Occlusion (Blockage) Sensor
17
Cartridge Sensor
17
Watertight
17
History
17
Description of Pump Display and Menus
18
Screensaver and Backlight
19
Menus
19
Editing Values
19
Timeout Feature
19
Home Screen Example
20
Sample Screens
20
Accessories
21
Cartridge
21
Infusion Sets
21
Before Using the Pump for the First Time
22
Insert a Battery
22
Self Tests
24
Setup
25
Opening the Setup Menu
26
Setup Menu - Time and Date
27
Setup Menu - Local Formats
28
Setup Menu - Alerts
29
Setup Menu - New Patient
31
Setup Menu - Delivery
32
Setup Menu - Security
34
Delivery Program
35
Using the Pump
37
Loading a Cartridge
37
Supplies Required
37
Filling the Cartridge
37
Attaching an Infusion or Extension Set and Loading a Filled Cartridge into the Pump
38
Fill the Tubing
42
Fill Cannula
43
Set Site Change Reminder and Restart Delivery
44
Stopping and Starting the Pump
45
Starting the Pump
46
Delivering a Demand Dose
47
Canceling Doses
48
Canceling a Dose (Demand or Automatic) While in Progress
49
Canceling Next Automatic Dose
49
History
50
Beep or Vibrate
52
Continuous Rate Menu
53
Automatic Dose Menu
54
Demand Dose Menu
55
Help
57
About Alarms (Beep/Vibrate Settings)
57
Troubleshooting
58
Alarms
58
Alerts
60
Other Messages
61
Cleaning the Pump
65
Servicing the Pump
66
The Pump and
67
Extreme Temperatures
67
Water
67
If the Pump Is Dropped or Hit Hard
67
Technical Information
69
Pump Development Standards
69
Specifications
75
General Specifications (Nominal)
75
Delivery Specifications
77
Main Menu
77
Setup
77
Delivery Program
78
Load
78
History
79
Accuracy Test Results
80
Safety Features and Fault Detection
82
Hardware Safety Features
82
Watchdog Timer Circuit
82
Motor Drive/Motor Watchdog Circuit
82
Voltage Detector Circuit
83
Software Safety Features
83
Hardware-Related Software Safety Features
83
Program Memory Check
83
RAM Memory Check
83
Motor Circuit Check
84
Keypad Encoder Check
84
Data Handling and Software Safety Features
84
Data Stored in RAM
84
Data Stored in NOVRAM
84
Data Used in Calculations
85
Timer Data Registers
85
Inspecting the Pump
86
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Smiths Medical CADD-MS 3 and is the answer not in the manual?
Ask a question
Smiths Medical CADD-MS 3 Specifications
General
Brand
Smiths Medical
Model
CADD-MS 3
Category
Medical Equipment
Language
English
Related product manuals
Smiths Medical CADD
10 pages
Smiths Medical CADD-Solis
64 pages
Smiths Medical CADD-legacy 1
32 pages
Smiths Medical CADD-Solis VIP
152 pages
Smiths Medical CADD-Prizm VIP
32 pages
Smiths Medical CADD-Legacy PCA
10 pages
Smiths Medical CADD-Legacy PLUS
2 pages
cadd-solis VIP 2120
44 pages
Smiths Medical CDS 9000
44 pages
Smiths Medical BCI SPECTRO2 30
4 pages
Pneupac babyPAC 100
64 pages
Medfusion 3000 Series
184 pages