SOLO BETA User Manual
Set the Motor’s Number of Poles
- Note: in SOLO you set the Number of Poles of the motor, and this is a parameter useful for
3 phase Motors and their accurate speed calculation. Notice that this is different with the
number of pole-pairs and the relation is as below:
Motor Number of Poles = Number of Pole-pairs * 2
Set the Number of Poles at 8:
FF FF 00 0F 00 00 00 08 00 FE

To check the written value:
Read the number of Poles:
FF FF 00 8F 00 00 00 00 00 FE
Change or Set/Reset the Device address:
The default device address on each SOLO upon delivery is 0, but you can change this value to
anything in between 0 to 254 or [0xFE]. For example in below you can see an example of how to
change the device address from 0 to 1, and then for reading it, instead of zero, we put 1, because
now our device address is set at 1 .
Set Device Address to 1

FF FF 00 01 00 00 00 01 00 FE
Read Device Address

FF FF 01 81 00 00 00 00 00 FE

By putting “0xFF” inside the device address using the command code “0x12” you can reset any
device address back to ZERO whenever you want. You can also “Reset Factory” the device to go
back to default address of 0.
www.solomotorcontrollers.com
January 2021 - Revision V_1.0.5 Copyright © 2020, All right Reversed. SOLO motor controllers.