*TST?
The  common query performs the self-test and returns the results. If an
error is detected during self-test, execution is immediately stopped.
. The waveform generator does not respond to any commands or queries
issued during the self-test. The self-test takes up to 90 seconds to complete.
CALIBRATION and DIAGNOSTIC
, , 


None

where  and  is one of following arguments.
 terminated without error
 detected an error in the CPU unit
 detected an error in the setup-related unit
700 detected an error in the waveform memory

might return 100 to indicate that errors were detected in the CPU unit.