Event message
Cause Remedy 1) 2)
No. Text
33 MinMax out
of Range
Wrong parame-
trisation
Q Parameterise again
34 Batterie-E-
Fuse open
The overcurrent
protection cir-
cuitry has trig-
gered or incor-
rect polarity was
detected.
Connect battery poles correctly. If the error
persists, contact your dealer.
X
Settings in-
compatible
Parameter file
not compatible
Q Save settings of a compatible device
on the SD card
File not found No valid
parameter file
found on SD
card
Q Save settings of a compatible device
on the SD card
79 HS400 com-
munication
failed
No communi-
cation possible
to registered
HS400, RS-485
communication
is interrupted.
Q Check cables. Connect the bus cables
again.
Q Check the slave power supply.
Q Eliminate the interruption, restart
HS400
1)
X = the event message triggers switching on of the alarm output.
2)
Type of event message