EasyManua.ls Logo

Steca Tarom 4545 - Checking the Charging Functionality; System

Steca Tarom 4545
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
67
DE
16.1.3 Checking the charging functionality
1. If the Battery symbol flashes, despite a long period of sunshine and correctly connected solar
module then measure the battery voltage.
2. If the battery voltage is very low then charge the battery with an external charger or replace
the battery.
3. Execute self test (section 15.3).
4. Contact your dealer if the batter voltage is greater than 17/34 VDC (Tarom 4545) or
17/34/68 VDC (Tarom 4545–48).
16.1.4 System
We recommend checking all system components at least once a year, according to the manufactur-
er's specifications. The following maintenance work is generally recommended:
Q Check the cable strain relief.
Q Check that all cable connections are secure.
Q Tighten screws if necessary.
Q Check all contacts for signs of corrosion.
Q Check the acid levels in the battery according to the manufacturer's specifications.

Table of Contents

Other manuals for Steca Tarom 4545

Related product manuals