18.4.1 Master data file
Header data in the created CSV file
Manufacturer Device name Serial number
Steca Elektronik GmbH Tarom 4545 or
Tarom 4545-48
20-digit serial number
Q Steca part number (6 digits)
Q Coded month/year of production
(2-digits)
Q Steca RM number (8 digits)
Q Consecutive number (4 digits)
Content of data file
Information/column Value
Date DD/MM/YYYY, according to the configured date format.
Time hh:mm:ss, according to the configured time format.
Vbat[V] BatteryvoltageatterminalsB+/B−.
SOC[%] Q SOC value
Q ‘-’ with the voltage control setting.
Ipv[A] PV current on the module input
Iin[A] Input current that is used on the device for battery charging and/or
load.
Iout[A] Load current that is taken from the load output of the device.
Ibat_total[A]SOC Current information according to the sources selected in the mem-
ber list in ‘Menu‘
‘Settings‘ ‘Battery‘ ‘Control mode‘ ‘Sensor
member list‘.
Q The currents of the selected sources are added according to
their prefix.
Q Charge current is displayed as positive ( ‘+’ )
Q Dischargecurrentisdisplayedasnegative(‘−’)
Icharge_total[A] Total of the selected energy input sources.
Iload_total[A] Total of the selected energy output sources.
ChargeMode Charge mode identifier: F, B, E, S.
ErrorState Error state: 0-No errors, 1-Information, 2-Warning, 3-Error.
ErrorNr Q Error code
Q '-' if no value is present.