18.4.3 PA HS400 data file
Header data in the created CSV file
StecaLink slave
address
Device name Serial number
40 – 49 HS400 18-digit serial number
Q Steca part number (6 digits),
Q Steca RM number (8 digits), consecutive number
(4 digits).
Contents of the CSV data file
Information/column Value
Date DD/MM/YYYY, according to the configured date format.
Time hh:mm, according to the configured time format.
I_integral Current information of the PA HS400 in A.
Position The current direction of the measuring position assigned to this sensor in
the master, '-' when no value is present.
1 – Not installed
2 – Charge sensor
3 – Discharge sensor
4 – Charge/Discharge sensor
SOC_relevant Use of the PA HS400
0 – Only displayed in the status window
1 – Sensor is taken into consideration for SOC calculation
Number_of_turns The number of turns configured for this sensor in the master.
Reading_inverted The current direction configured for this sensor in the master.
0 – Value not inverted
1 – Value inverted