Chapter 7 Parameter Explanation
ET/EP/EH Series Intelligent Flexible Driver Manual
- 93 -
inspection. The motor is normally synchronous motor. During each patrol inspection, let the motor
run with no load for some time to ensure it functions normally.
7.3.6 P15 group SVC parameter
Initial magnetic pole
judgment
0: No judgment No load starting capability, requiring long acceleration time.
1: DC injection starting Incrementally inject DC current to (P15.05* motor rated current), and drag
the motor magnetic pole to the excitation direction.
2: Pulse voltage injection starting Inject voltage pulses to conduct initial magnetic pole judgment.
With the motor rated current, pay attention to this parameter setting in the load start.
Pulse injection amplitude
(%)
Use this parameter when P15.00=2 in the open-loop vector control PM control mode.
During P15.00=2 in the open-loop vector control PM control mode, it needs to use pulse angle
compensation function when encountering few special motors.
Control mode selection, recommending default control word mode 2.
PM current control strategy
Default 1: MTPA requiring motor static self-learning.
MTPA loop adjusts the bandwidth, default is 10 Hz, no modification is needed generally