ET/EP/EH Series Intelligent Flexible Driver Manual
- 173 -
Appendix D Profinet Communication
Description
D.1 Introduction to Network Settings
D.1.1 Introduction to PN communication card of STEP inverter
* Model of STEP inverter PN communication card is AS.L03/C9. The image is as follows:
D.1.2 Host setting
* The PROFINET slave file (. xml) must be configured in the master station, with three types of
protocols integrated internally: 2WORD, 4WORD, and 8WORD. Users can choose according to
their actual needs., automatically identifying protocol types from opportunities.
* Set the name and IP address of each PROFINET slave station in TIA Portal software.
D.1.3 Slave setting
* The PROFINET slave station (STEP inverter) sets the running command and speed preset to
PROFINET in the P10 group parameter.
D.1.4 GSD file acquisition
* GSD file name is GSDML-V2.32-STEP-Profinet Adapter-XX.xml.
Please contact the product manager to obtain the GSD file.